Fire-rated sealing and fire stopping
Fire-rated and intumescent sealant around service penetrations and linear gaps in fire-resisting walls and floors, installed to the manufacturer’s tested details where it is specified.
- Holes left around new cables or pipes after M&E work
- Gaps opened up during a fit-out or refurbishment
- Foam or general-purpose sealant in openings the specification marks for a fire-rated product
Fire-rated sealing and fire stopping: send details for a fixed quote
Send drawings, photos or a joint schedule, or tell us about the site, and we’ll come back with a fixed quote.
What fire-rated sealing and fire stopping covers
Fire-resisting walls and floors divide a building into compartments so that fire and smoke are held back. Each service that crosses one, whether pipework, cabling or ductwork, leaves an opening, and so do the joints where walls meet floors and soffits. Those gaps have to be sealed with products tested for that use, or the compartment is compromised. Where it is specified, we install fire-rated and intumescent sealant at service penetrations and along linear gaps, to the product’s tested detail. That means matching the product, the wall or floor type, the services passing through, the gap size, the depth and any backing, such as mineral wool if the tested detail requires it. Much of this work follows M&E installations, refurbishments and fit-outs, when new services have been run through existing walls. Fire stopping design and sign-off sit with the designer, fire engineer or building control. We work to the specification and the manufacturer’s installation guidance.
We work across South East England, Greater London and all of Scotland. Our workmanship carries a 12-month guarantee, we’re CHAS accredited and a Constructionline member, and our applicators hold CSCS cards.
Problems we put right
- Holes left around new cables or pipes after M&E work
- Gaps opened up during a fit-out or refurbishment
- Foam or general-purpose sealant in openings the specification marks for a fire-rated product
- Linear gaps at wall heads left open or packed with the wrong material
- Seals that don’t match the product’s tested detail
- No clear picture of what has been sealed and with what
Joints and areas we seal
- Pipe penetrations
- Cable penetrations
- Small duct penetrations where the tested detail allows
- Linear gaps at wall heads
- Joints between fire-resisting walls and floors
- Service gaps in risers

At a glance
- Fixed quote, scope in writing
- CSCS-carded applicators
- CHAS accredited · Constructionline member
- £5m public liability insurance
- 12-month guarantee
How it works
- Send the specification, drawings marking fire-resisting construction, and photos of the penetrations.
- We check that fire-rated sealant is the specified product for each opening, and tell you if a detail calls for something else.
- You receive a fixed quote listing the areas and the products to be used.
- Gaps are cleaned out, and backing is fitted where the tested detail requires it.
- Sealant is applied to the depth and gap size set out in the product’s tested detail.
- We hand over the records agreed at quote stage, so your team can update its fire-stopping information.
We install to the specification
Fire stopping is designed and signed off by others: the designer or principal designer, the fire engineer where there is one, and building control. Our role is to install what has been specified, using the right product for the wall or floor and the services passing through it. We do not design fire stopping and we do not certify it. We don’t hold a third-party fire-stopping installer certificate, so if your project requires one, please tell us at enquiry stage.
Why the tested detail matters
Penetration seals are tested to BS EN 1366-3 and linear joint seals to BS EN 1366-4, with results classified under BS EN 13501-2, for example EI 60 or EI 120. A test result only covers what was tested: the same product, substrate, service type and size, gap, depth, backing and orientation. Mixing products or improvising on site undermines that evidence, so we follow the manufacturer’s detail exactly.
Sealant is one product among several
Fire-rated sealant suits many cable and small pipe penetrations and linear gaps, but it is not the answer to every opening. Plastic pipes, larger ducts and big service openings often need collars, wraps, batts, boards or pillows instead. If the specified detail calls for a product other than sealant, we’ll tell you, rather than filling the gap with whatever is to hand.
After M&E and fit-out works
New data cabling, pipework and ductwork are among the commonest reasons fire stopping gets breached in existing buildings, and a check of fire-resisting walls and floors once the M&E trades leave is good practice. The rules differ by country: Approved Document B covers England, while in Scotland the Technical Handbook expects service penetrations to keep at least the fire resistance of the wall or floor.
Why it’s worth doing now
Gaps around pipes, cables and ducts in fire-resisting walls and floors can let fire and smoke spread between compartments. They are often opened by later trades and never closed properly. Sealing them with the specified product, to its tested detail, restores what the wall or floor was designed to do.
What affects the quote
We don’t publish set prices, because no two buildings are the same. Send details and we’ll give you a fixed quote before we start. The main things that affect it are:
- How many metres of joint there are, and how many areas, elevations or sites
- How much failed sealant has to come out, and how hard it is
- Joint size, depth and whether backing rod or primer is needed
- Access: height, scaffold or MEWP access arranged by others, occupied areas
- The product the joint needs (and colour, where it matters)
- Programme, phasing and site requirements such as permits and inductions
What a good quote includes
- All failed sealant removed, never sealed over
- The product named for each joint type
- What the 12-month guarantee covers
- When each area can be used again
- Who is doing the work, their CSCS cards and the insurance in place
- What site paperwork and records are included
Aftercare
Keep a record of where fire-rated sealant has been installed and which product was used. Make sure anyone who drills through those walls or floors later knows they must reinstate the seal to a tested detail, and check penetrations after every fit-out or M&E change.
Trusted. Accredited. Insured.
Fire-rated sealing and fire stopping: common questions
Do you hold a third-party fire-stopping installer certificate?
No. Our work is installing fire-rated and intumescent sealant, where specified, to the product’s tested detail. If your project requires third-party certification, tell us at enquiry stage.
Who signs off the fire stopping?
The designer, fire engineer or building control, depending on the project. We work to the specification they set.
Can you seal around plastic pipes?
Only where the specified product’s tested detail covers that pipe. Plastic pipes often need collars or wraps, and we’ll tell you if so.
What records do you provide?
Tell us what records you need and we’ll confirm with the quote.
How do fire-rated and intumescent sealants differ?
Intumescent sealant swells when heated, helping to close the gap as nearby materials soften. Other fire-rated sealants rely on their tested make-up rather than expansion. The tested detail decides which is used.
Do you give a fixed price before you start?
Yes. Send photos, drawings or a joint schedule, or we can visit, and we’ll give you a fixed quote with the scope in writing before any work starts.
Are you accredited and insured?
Yes. We’re CHAS accredited and a Constructionline member, our applicators hold CSCS cards, and we carry £5m public liability insurance.
Page updated 3 November 2026
Near you
Find fire-rated sealing and fire stopping in your town:
- London
- Glasgow
- Edinburgh
- Aberdeen
- Dundee
- Southampton
- Portsmouth
- Brighton
- Reading
- Oxford
- Guildford
- Chelmsford
- Maidstone
- Milton Keynes
- Watford
- Basildon
Advice
- Fire Stopping Explained for Building Owners
- Fire-Rated vs Intumescent Sealant Explained
- Fire Stopping After M&E and Fit-Out Works
- Building Safety Act and Fire Stopping Records
- Fire Stopping and Scotland's Building Standards