The Mastic Doctor team standing beside their branded vans outside an office building
East Lothian · Scotland

Fire stopping in Innerwick

Sealant work in Innerwick for main contractors, managing agents and facilities managers: fire-rated and intumescent sealing of service penetrations and linear gaps, quoted at a fixed price.

  • Expanding foam used as fire stopping
  • Unsealed openings around new pipes and cables
  • Head-of-wall gaps with no fire seal
1
Send details
Photos, drawings or a schedule, or we visit.
2
Get a quote
A fixed price, with what’s included set out clearly.
3
We seal
CSCS-carded applicators, the right product for each joint.
4
Guaranteed
Signed off, with 12 months’ guarantee.
South East, London & Scotland
Constructionline member
Fully insured: £5m PL

Fire stopping across Innerwick

Tell us what needs sealing and where, with photos or drawings if you have them, and we’ll price it.

Questions we are asked in Innerwick

Which Scottish guidance covers penetration seals in Innerwick?

Scotland’s non-domestic Technical Handbook covers it in clause 2.1.14: penetrations keep at least the element’s fire resistance duration, with products tested for their end use. The detail is set by the designer and goes through the warrant process; we install the specified product to its tested detail.

Is hospital work, at somewhere like Belhaven Hospital, something you do?

Yes, healthcare and care buildings are part of our work. The estates team’s permit system and infection-control rules come first, and the work is planned around them.

What happens if old sealant might contain asbestos?

Managing asbestos is the dutyholder’s responsibility, so for older buildings we ask for the asbestos register first. If anything suspect turns up, we stop until it’s tested.

Do you seal on top of existing sealant?

No, never. Sealing over old material is one of the classic causes of early joint failure, so everything comes out first.

What do you charge?

There isn’t a price list, because every site is different. With photographs or drawings, we can give you a fixed quote.

Do you offer coloured sealant?

In many cases, yes. Many products come in a range of standard colours, and matching to RAL references or surrounding finishes is often possible. We confirm what’s available for the specified product when we quote.

Does the weather affect the work?

It can, for external work. Wet joints and cold, damp or frosty conditions stop the sealant bonding properly, so external work may be moved if conditions aren’t right. Internal work is far less affected.

About our fire stopping in Innerwick

Where pipes, cables and other services cross a compartment wall or floor, the opening around them has to be closed so fire and smoke can’t move between compartments. Our part is installing fire-rated and intumescent sealant at those openings and along linear gaps, where the specification calls for it. We work to the product’s tested detail for every seal. If you have old intumescent sealant that has split away and unsealed openings around new pipes and cables, we can put it right, on cable penetrations, pipe penetrations and service gaps in risers alike. Whether you call it commercial sealant work, mastic application or joint sealing, in Innerwick it comes down to the same thing: failed joints cut out, faces prepared and the right sealant laid to the right depth.

Around smaller places such as Innerwick, compartment walls and floors tend to be in schools, hotels, care homes and community buildings. Those penetrations are closed with the product the specification names, built up as tested.

Guaranteed is the last step of every job. You get a 12-month guarantee on our workmanship, and the quote explains what it covers.

Location
Innerwick (EH42)
Wider area
East Lothian
Guarantee
A 12-month guarantee
Price
Fixed quote, scope in writing
Phone
01277 525 020
Last updated
3 November 2026
The Mastic Doctor team beside their liveried vans in front of an office building

Penetration seals near Innerwick

Scottish guidance (non-domestic Technical Handbook, clause 2.1.14) asks that penetrations match at least the fire resistance period of the element they pass through, with proprietary products, intumescent ones included, tested for their end use. We install fire-rated sealant to that tested detail where it is specified.

For a building such as Innerwick Parish Church, new heating or data runs are the usual reason penetrations need sealing.

Innerwick is about 13 miles east of Haddington, in East Lothian. We cover Innerwick, and jobs here get the same fixed quote and 12-month guarantee as anywhere else. 48 places across East Lothian fall within our area, including Innerwick. For work in that direction, see our Edinburgh page.

If you need fire stopping in EH42, the process matches everywhere else we work: send details, get a quote, we seal, guaranteed. For a building on Back Lane, Manse View and Kirk Brae or nearby, send details and we will quote for service penetrations. Just outside Innerwick, we also work in Broxburn (3 miles north-west), Spott (3 miles west), Cockburnspath (4 miles south-east), Dunbar (4 miles north-west) and Cove (4 miles east). Nearby towns on our patch include Haddington (13 miles west), North Berwick (13 miles north-west), Gullane (15 miles west) and East Linton (8 miles west).

Around Innerwick

Innerwick’s nearest station is Dunbar station, roughly 3.8 miles north-west of the centre. Nearby you’ll also find Innerwick Castle (0.9 miles east) and Belhaven Hospital (4.3 miles north-west). For a walk, there’s Doon Hill and Pease Dean.

Map of Innerwick © OpenStreetMap contributors

Why act early in Innerwick

The longer openings stay, the more there tend to be: every new cable or pipe adds another. Keeping on top of it after each round of works keeps the job small and avoids a much larger catch-up later. Buildings that aren’t in daily use, such as halls and seasonal premises, may let water in unnoticed, giving water time to get in. Resealing early avoids that.

No two sites price the same: the joint sizes, the specified product, access and working hours each have a bearing. Send the details and a fixed figure follows.

Why choose Mastic Doctor in Innerwick

  • Our applicators hold CSCS cards
  • One number for every site we cover
  • Clear, fixed quotes
  • Over 20 years of commercial sealing

Read how commercial sealant jobs are priced or our accreditations.

Honest limits

A proper diagnosis includes knowing what sealant can’t do. We will tell you if the real problem is any of the following:

  • Reviewing a building’s overall fire safety
  • Writing the fire-stopping specification
  • Issuing fire ratings or certificates for seals

Not sure which it is? You can speak to us on 01277 525 020 or email drawings and photos and we’ll tell you honestly.

Joints and surfaces we work on

  • Linear gaps at wall heads
  • Service gaps in risers
  • Pipe penetrations
  • Joints between fire-resisting walls and floors
  • Small duct penetrations where the tested detail allows
  • Cable penetrations

After the work

Cleaning and maintenance staff play a part too. Share these points with them:

  • Foam or ordinary sealant is never a fire-seal repair
  • Record which product was used where
  • Include service cupboards in routine inspections
  • Put resealing into every M&E and fit-out package

After the work, brief anyone else working in the area that the openings are now sealed. Any seal cut back for a new service needs reinstating to its tested detail using the same product.

Write fire stopping into the scope of any work crossing a compartment wall or floor. That way the opening is sealed while the trade and access are still there.

Do you need fire stopping in Innerwick?

On a busy project, programme pressure can mean fire stopping is rushed or left to whichever trade is closest. That is when untested combinations creep in, which then have to be put right.

Look out for the following:

  • Non-fire-rated filler around services
  • Fire sealant pulled out of the opening
  • Open linear gaps along the top of fire-resisting walls
  • Penetration schedules that need working through

Hospital estates such as Belhaven Hospital (to the north-west of Innerwick) are divided into fire compartments, and any service penetration through them should be sealed to the specified, tested detail.

Questions to ask before you book

  • Their pre-qualification and accreditations
  • Who will actually carry out the work
  • Proof of insurance
  • Is the sealant right for the movement and the substrate?

Our contractor checklist

Our process

In a busy building, we agree a sequence with your contact so the disruption stays in one area at once. Each section is protected, cleaned back and sealed before we move to the next. For work around Innerwick, we aim for one trip, which is why we ask for photographs and a full list first. Outside work also needs a suitable weather window.

  1. First we go through the drawings, schedule or specification for the seals and raise any questions before we price.
  2. Every penetration is compared with its detail: wall or floor type, service, gap size and depth.
  3. Anything that doesn’t belong in the opening, such as expanding foam or general-purpose filler, is removed.
  4. We fit the backing the detail asks for, to the stated depth.
  5. Fire-rated or intumescent sealant is gunned in to the specified depth, then tooled.
  6. If an opening needs something other than sealant, we tell you instead of improvising.

Getting the site ready

  • Have the specification and drawings to hand
  • For older buildings, check the asbestos register before work
  • Let building users know which areas are affected

Get a fixed quote

Send details, get a quote, we seal, guaranteed: that’s how every job runs. To take the first step, phone 01277 525 020 or send details through our quote form.

Get a price

Advice

When to bring in a specialist

Site maintenance staff can often handle a short internal joint. The usual problems come from preparation: new sealant over old, damp or dusty faces, or the wrong product for the movement.

The visible bead is only part of the job. Correct depth, the right primer and a sealant matched to the movement are easy to get wrong without experience.

Accreditations

Trusted. Accredited. Insured.